Part Number Hot Search : 
X9269 AS1112 06H5F MDR5100 FM101 PL201 06H5F SM5828
Product Description
Full Text Search
 

To Download THP3-2411 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  http://www.tracopower.com dc/dc converters thp 3 series, 3 watt features supplementary and reinforced insulation i/o isolation 3000 vacrms rated for 300 vrms working voltage medical safety to ul 60601-1 and iec/en 60601-1 3rd edition, 2 x moop industrial safety to iec/en/ul 60950-1 9-40 vdc, 18-80 vdc and 36-160 vdc extended operating temperature range C40c to 85c max. input flter meets en55022a without ext. components continuous short circuit protection high reliability, mtbf >1 mio. hours lead free design, rohs compliant 3-year product warranty the thp-3 series is a new range of high performance 3w dc/dc converters in a low profle dil-24 package with standard industry pin-out. the very high i/o- isolation system of these converters and input voltages up to 160 vdc make this product the best choice for many demanding applications in railroad and transpor - tation systems, medical equipment, instrumentation, everywhere where high basic-, supplementary- or reinforced insulation is requested to meet specifc safety stan - dards. a high effciency allows safe operation in a temperature range of C40c to +75c at full load. full smd-design with exclusive use of ceramic capacitors ensure a very high reliability and a long product lifetime. order code input voltage range output voltage output current max. effciency typ. thp 3-2411 5 vdc 600 ma 78 % thp 3-2412 9 C 40 vdc 12 vdc 250 ma 83 % thp 3-2422 (24 vdc nominal) 12 vdc 125 ma 83 % thp 3-2423 15 vdc 100 ma 83 % thp 3-4811 5 vdc 600 ma 78 % thp 3-4812 18 C 80 vdc 12 vdc 250 ma 83 % thp 3-4822 (48 vdc nominal) 12 vdc 125 ma 83 % thp 3-4823 15 vdc 100 ma 83 % thp 3-7211 5 vdc 600 ma 78 % thp 3-7212 36 C 160 vdc 12 vdc 250 ma 83 % thp 3-7222 (72 vdc nominal) 12 vdc 125 ma 83 % thp 3-7223 15 vdc 100 ma 83 % models u l 60950 -1 ul 60601-1 page 1 of 3 c b scheme
http://www.tracopower.com dc/dc converters thp 3 series 3 watt input specifications input current at no load / full load 24 vin models: 20 ma typ. / 160 ma typ. 48 vin models: 10 ma typ. / 100 ma typ. 72 vin models: 5 ma typ. / 85 ma typ. start-up voltage / under voltage shut down 24 vin models: 9 vdc / 8.5 vdc 48 vin models: 17 vdc / 16 vdc 72 vin models: 34 vdc / 32 vdc recommended external input fuse (slow blow) 24 vin models: 1.0 a 48 vin models: 0.6 a 72 vin models: 0.3 a surge voltage (1 sec. max.) 24 vin models: 50 v max. 48 vin models: 100 v max. 72 vin models: 180 v max. reverse voltage protection 0.3 a max. input filter en 55022 class a, fcc part 15, class a output specifications voltage set accuracy 1 % voltage balance (dual output models) 2 % max. regulation C input variation vin min. to vin max. 0.5 % max. C load variation 25 C 100 %: 1.0 % max. minimum load 15 % of rated max. output current. (operation at lower load is safe but major deviations to specifyed data may occur) ripple and noise (20 mhz bandwidth) 5 vdc models: 75 mvpk-pk typ. other models: 100 mvpk-pk typ. temperature coefficient 0.02 %/k typ. current limitation >120 % iout max. startup rise time 0 % to 100 % vout 25 ms max. short circuit protection indefinite (automatic recovery) capacitive load 5 vdc models: 1000 f max. 12 vdc models: 470 f max. dual output models: 220 f max. (each output) isolation / safety i/o isolation test voltage (flash tested 1 sec.) 6000 vpk i/o isolation voltage (50hz, 60sec.) 3000 vacrms, rated for 300 vrms working voltage, 2 x moop leakage current (at 240vac, 60hz) 2 a i/o isolation capacitance (at 100khz, 1v) 7 pf typ. i/o isolation resistance (at 500vdc) >1000 mohm safety standards iec/en 60950-1, ul 60950-1 csa c22.2 no. 60950-1-03 iec/en 60601-1 3rd edition, 2 x moop, ul 60601-1, csa c22.2 no. 601.1 safety approvals C cb test report according iec 60950-1 www.tracopower.com/products/thp3-cb60950.pdf C cb test report according iec 60601-1 www.tracopower.com/products/thp3-cb60601.pdf C csa certificate according ul 60950-1/60601-1 www.tracopower.com/products/thp3-csa.pdf all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. page 2 of 3
dc/dc converters thp 3 series 3 watt outline dimensions re v. 10/12 pin single dual 1 +vin (vcc) +vin (vcc) 11 no pin common 12 Cvout no pin 13 +vout Cvout 15 no pin +vout 23 Cvin (gnd) Cvin (gnd) 24 Cvin (gnd) Cvin (gnd) pin-out dimensions in [mm], () = inch pin diameter ? 0.6 0.05 (0.024 0.002) tolerances 0.5 (0.02) pin pich tolerances 0.2 (0.01) specifcations can be changed any time without notice. general specifications temperature ranges C operating C40c to +85c C casing +95c max. C storage C40c to +125c derating 3.3 %/k above +70c humidity (non condensing) 95 % rel h max. reliability, calculated mtbf (mil-hdbk-217f, at +25c ground benign) >1 mio. h switching frequency 150 khz typ. (puls width modulation) casing material non conductive plastic (ul 94v-0-rated) potting material silicon tse 3331 (ul 94v-0-rated) weight 16.2 g (0.57 oz) soldering temperature max. 265c / 10 sec. altitude during operation up to 5000 m (16400 ft) approved environmental compliance C reach www.tracopower.com/products/thp3-reach.pdf C rohs rohs directive 2011/65/eu page 3 of 3 31.8 2x2.54 20.32 2.54 2.0 0.2 10.5 3.9 (1.25) (0.8) (0.1) (2x0.1) (0.08) (0.41) (0.15) (0.008) 2.54 20.3 15.2 (0.8) (0.6) (0.1) bottom view 11 1 12 13 15 23 24 application note: www.tracopower.com/products/thp3-application.pdf - the component is not be used in an oxygen rich environment. - the component is not to be used in conjunction with fammable anaesthetics and agents. - the component has to be disposed appropriately. please refer to local regulations (waste electrical and electronic equipment). - a modifcation of the component is not allowed. jenatschstrasse 1 ch-8002 zurich switzerland t el. +41 43 311 45 11 fax +41 43 311 45 45 info@traco.ch www .tracopower .com


▲Up To Search▲   

 
Price & Availability of THP3-2411

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X